Free service hotline
400-7558988
TEL: 0769-85075888-6618
13925591357
Fax: 0769-85075898
Mail: net04@gtggroup.com
ADD: Huacan Industrial Park, No. 2 Keji 8th Road, Songshan Lake Park, Dongguan City, Guangdong Province
1、 The necessity of certification
Legal mandatory requirement: Failure to pass KC certification will result in customs detention and face a maximum fine of 30 million Korean won and recall risk
E-commerce platform requirements: Korean Coupang/Naver and other platforms must display KC certification numbers
2、 Core certification type
KC Safety Certification
Suitable for all types of baby monitors
Management organization: Korea Institute of Technical Standards (KATS)
KC-RF certification
Required condition: Includes wireless functions such as Wi Fi/Bluetooth
Management organization: Korea Radio Research Agency (RRA)
3、 Certification process (6-8 weeks)
preliminary preparation
Confirm applicable standards:
Safety standard: KS IEC 60335-2-XX
Wireless standard: KN 301 489-1
Choose a Korean authorized laboratory (such as GTG Guangce Group)
Technical document preparation
Korean instruction manual (including safety warnings and applicable age)
Circuit diagram and PCB layout diagram
Key component certification documents (UL/VDE certificates)
Sample requirement: 3 complete machines (including matching power adapters)
Laboratory testing projects
Electrical safety testing:
Voltage withstand test: 1500V/60 seconds (leakage current ≤ 0.5mA)
Temperature rise test: shell temperature ≤ 60 ℃
Mechanical safety testing:
1-meter drop test (shell intact/functional)
Chemical safety testing:
Heavy metal detection: lead ≤ 90ppm, cadmium ≤ 75ppm
Wireless Radio Frequency Test (KC-RF):
2.4GHz frequency band transmission power ≤ 20dBm
Factory Audit
First certification and annual mandatory review
Review focus:
Battery assembly process record (welding material batch number+operator number)
Incoming inspection report (batteries must comply with KS C IEC 62133)
Evidence collection and annotation
KC Logo Specification:
Size ≥ 5mm
Label certification number (format example: KR-X-XXX-XXXXX)
The product must be labeled with:
Voltage parameters (110V/220V 60Hz)
Manufacturer information
Korean agent contact information