Welcome to GCDC official website!

About GCDC

Professional organization for wireless/electromagnetic compatibility testing

Current location: Home Experimental Base EMC Laboratory

EMC Laboratory

Edit: GCDC Affiliation: Experimental Base Views: 2110
10m Darkroom
3m Darkroom
3m Darkroom
3m Darkroom
3m Darkroom
3m Darkroom
Conduction Test System
Conduction Test System
Conduction Test System
Conduction Test System
Power Radiation
Three loop antenna
Immunity Room
Conducted anti-interference test system
Radiation immunity test system
Electrical Fast Transient Burst Generator
Electrostatic Discharge Simulator Generator
Lightning Tester
Harmonic Voltage Fluctuation Analyzer
Three-phase artificial power network
Voltage Dip Short Interrupt Generator
10m Darkroom

10m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

3m Darkroom

Conduction Test System

Conduction Test System

Conduction Test System

Conduction Test System

Conduction Test System

Conduction Test System

Conduction Test System

Conduction Test System

Power Radiation

Power Radiation

Three loop antenna

Three loop antenna

Immunity Room

Immunity Room

Conducted anti-interference test system

Conducted anti-interference test system

Radiation immunity test system

Radiation immunity test system

Electrical Fast Transient Burst Generator

Electrical Fast Transient Burst Generator

Electrostatic Discharge Simulator Generator

Electrostatic Discharge Simulator Generator

Lightning Tester

Lightning Tester

Harmonic Voltage Fluctuation Analyzer

Harmonic Voltage Fluctuation Analyzer

Three-phase artificial power network

Three-phase artificial power network

Voltage Dip Short Interrupt Generator

Voltage Dip Short Interrupt Generator

1. Introduction to EMC Electromagnetic Compatibility Testing

Electromagnetic compatibility laboratory is a special type of laboratory established for electromagnetic compatibility testing. First explain the basic concept of electromagnetic compatibility: it refers to the ability of electromagnetic systems and subsystems to work normally in their respective electromagnetic environments without degrading their performance due to electromagnetic interference. In order to verify whether the EMC design of electronic and electrical equipment is good, it is necessary to test the emission interference and transmission characteristics of various electromagnetic interference sources and whether the interfered equipment can withstand the load during the entire process of research and development, and verify whether the equipment meets the relevant electromagnetic compatibility. Standards and Specifications.

 

2. Extensive Electromagnetic Measurement——Introduction of EMC Electromagnetic Compatibility Laboratory

GCDC EMC Laboratory has established complete electromagnetic compatibility (EMI, EMS) capabilities in South China, with one 10m anechoic chamber, four 3m anechoic chambers, five shielded rooms and EMS anti-interference rooms; of which 10m Fahe a 9*6*6 meets the EMC test requirements of medical equipment, the maximum voltage and current can reach 380V/200A (three-phase) and 1000V/200 (DC), with wide test capability and accurate test data, it can provide complete CE, FCC, VCCI and other national EMC regulations and pre-test services.

 

3. Electromagnetic Compatibility Certification Project

Americas: FCC SDOC, FCC ID, ICES, ISED ID, etc.;

Europe: CE-EMC, etc.;

Asia: CCC, CQC, BSMI, KC, VCCI, PSE, etc.;

Australia: C-TICK, RCM, etc.;

 

4. Electromagnetic Compatibility Testing Items

Electromagnetic compatibility testing includes electromagnetic interference testing (EMI) and electromagnetic susceptibility testing (EMS). Electromagnetic Compatibility Standards require that products related to electronic and electrical equipment must meet the emission specifications of radiated interference and conducted interference, as well as the specifications of radiation tolerance and conduction tolerance.

(1) Electromagnetic interference (EMI, including CE and RE), the main contents of the test are: the test of the conduction interference and radiation interference emission of electronic and electrical products and equipment in various electromagnetic noise environments, and the interference during various signal transmissions Test of transfer characteristics.

(2) The main contents of the electromagnetic susceptibility (EMS, including CS and RS) test are:

1. Radiation tolerance test for electric field and magnetic field;

2. Conduction tolerance test for injected interference of power lines, control lines, signal lines, ground lines, etc.;

3. Tolerance test for electrostatic discharge and various transient electromagnetic waves (surge or electrical fast transient).

5. Electromagnetic Compatibility Testing Standards

Product Category CISPR/IEC standard European standard US/Canadian Standard Australian Standards Chinese standard Korean Standard Japanese standard
Information Technology/Audio Video

CISPR 32
CISPR 35
IEC 61000-3-2
IEC 61000-3-3

EN 55032
EN 55035
EN 61000-3-2
EN 61000-3-3

FCC PART 15B
ICES-003

AS/NZS CISPR 32

GB/T 9254.1
GB/T 9254.2
GB 17625.1
CNS 15936

KS C 9832
KS C 9835

V-3
V-4
J 55032(H29)

lamps

CISPR 15
IEC 61547
IEC 61000-3-2
IEC 61000-3-3

EN 55015
EN 61547
EN 61000-3-2
EN 61000-3-3

FCC PART 15B
FCC PART 18
ICES-005

AS CISPR 15
AS/NZS CISPR 32+AMD1

GB/T 17743
GB/T 18595
GB 17625.1
CNS 14115

KS C 9815
KS C 9547

J 55015(H29)

home appliances

CISPR 14.1
CISPR 14.2
IEC 61000-3-2
IEC 61000-3-3

EN 55014-1
EN 55014-2
EN 61000-3-2
EN 61000-3-3

FCC PART 15B

AS CISPR 14.1

GB 4343.1
GB 17625.1
GB 17625.2
CNS 13783-1

KS C 9814-1
KS C 9814-2

J 55014

industry, science, medical

CISPR 11
IEC 61000-4 Series Basic Standards
IEC 61000-3-2
IEC 61000-3-3

EN 55011,
EN 61000-4 Series Basic Standards
EN 61000-3-2
EN 61000-3-3

FCC PART 18
ICES-001

AS CISPR 11

GB 4824
GB 17625.1
GB 17625.2
CNS 13803

KS C 9811
KS C 9610-4Series Basic Standards

J 55011

Battery

IEC 61000-6-1
IEC 61000-6-2
IEC 61000-6-3
IEC 61000-6-4

EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4

FCC PART 15B
ICES-003

AS/NZS 61000.6.1
AS/NZS 61000.6.2
AS/NZS 61000.6.3
AS/NZS 61000.6.4

GB/T 17799.1
GB/T 17799.2
GB 17799.3
GB 17799.4

-

-

 

6. Electromagnetic Compatibility Laboratory

test site Pilot projects standard Remark
3m method full anechoic chamber

radiation emission 

GB4824-2004(CISPR11-2003) 

GB9254-2008(CISPR22-2006) 

30MHz 

Radiated Immunity 

GB17626.3-2006(IEC61000-4-3:2002) 

80MHz 

Conducted immunity measurement shielded room Electrical fast transient burst immunity test

GB17626.4 

Radiated Immunity
Immunity to Conducted Disturbances Induced by RF Fields

GB17626.6 

up to 30V
Insertion loss test for electrical lighting and similar equipment

GB17743 

9KHz-30MHz 

Radiation electromagnetic disturbance test of electric lighting and similar equipment

GB17743 

 

Harmonic flicker measurement shielded room Harmonic current emission test

GB17625.1-2012(IEC 61000-3-2:2009) 

GB17625.6-2003(IEC 61000-3-4:1998) 

GB17625.7-2013 

up to 75A 

Voltage changes, voltage fluctuations and flickering 

GB17625.2-2007(IEC 61000-3-3:2005) 

GB17625.3-2000(IEC 61000-3-5:1994) 

up to 100A 

AC Power Port Harmonic Immunity

GB17626.13-2006(IEC 61000-4-13:2002) 

up to 100A
Voltage fluctuation immunity test

GB17626.14-2005(IEC 61000-4-14:2002) 

up to 100A
DC Ripple Immunity

GB17626.17-2005(IEC 61000-4-17:2002) 

up to 100A
Three-phase voltage unbalance test

GB17626.27-2006(IEC 61000-4-27:2000) 

up to 100A
Power frequency frequency variation immunity

GB17626.28-2006(IEC 61000-4-28:2001) 

up to 100A
Voltage dips, short interruptions and voltage changes greater than 16A

GB17626.34-2012(IEC 61000-4-34:2009) 

up to 100A

Voltage dips, short interruptions and voltage changes at DC power input ports 

GB17626.29-2006(IEC 61000-4-29:2000) 

up to 100A
Electrostatic discharge measurement shielding room Electrostatic Discharge Immunity Test

GB17626.2-2006(IEC 61000-4-2:2001) 

Up to 30kV

Voltage dips, short interruptions and voltage changes 

GB17626.11-2008(IEC 61000-4-11:2004) 

Up to 100A; power off (0-100%) 

Low Frequency Common Mode Conducted Immunity

GB17626.16-2007(IEC 61000-4-16:2002) 

The highest disturbance level 30V
Shielded room for transient immunity measurement

Surge Immunity 

GB17626.5-2008(IEC 61000-4-5:2005) 

Up to 10kV
Damped Oscillating Magnetic Field Immunity

GB17626.10-1998(IEC 61000-4-10:1993) 

Up to 3kV; three-phase 440V /100A; 

Oscillatory wave immunity test

GB17626.12-1998(IEC 61000-4-12:1995) 

Up to 3kV; three-phase 440V /100A 

Power Frequency Magnetic Field Immunity

GB17626.8-2006(IEC 61000-4-8:2001) 

Short time up to 1000A/m
Pulse Magnetic Field Immunity

GB17626.9-2011(IEC 61000-4-9:2001) 

Up to 2000A/m

Online Application

Service line 13925591357

*

*

*

*

Please fill in the real information, we will contact you within 24 hours!

Consultation

Related Suggestion

View All
Title Introduction

RF Laboratory

GCDC RF Laboratory has multiple sets of international leading Bluetooth and WIFI…

RF Laboratory

Bluetooth Lab

1. Introduction to Bluetooth testing The test items required for Bluetooth qu…

Bluetooth Lab

LoT Lab

1. Introduction to the Internet of Things The Internet of Things (IoT) refers…

LoT Lab

5G Communication Laboratory

1. Introduction to 5G communication technology "4G changes life, 5G chan…

5G Communication Laboratory

SAR Laboratory

1. Introduction to SAR detection SAR (Specific Absorption Rate), electromagne…

SAR Laboratory

OTA Laboratory

1. Introduction to OTA testing OTA is the abbreviation of Over the Air in Eng…

OTA Laboratory

Safety Laboratory

1. Introduction to safety testing Safety regulations are safety regulations. …

Safety Laboratory

Energy Efficiency Laboratory

1. Introduction of Energy Efficiency Laboratory The energy efficiency laborat…

Energy Efficiency Laboratory

Reliability Lab

1. Introduction to Environmental Reliability Testing With the rapid developme…

Reliability Lab

Chemistry Lab

1. Introduction to chemical detection Electronic and electrical products are …

Chemistry Lab

TEL

Service Hotline

400-7558988 13925591357

WeChat

二维码Add Wechat

QQ

QQ consultation

2123664179